Operating the machine
24
The interval off LED lights up.
Two bars (--)or the last set sieve time light up in the time display.
The AS450 is now ready for operation without interval and for continuous operation
with a vibration amplitude of 1.0 mm.
Pos: 7.21 /00005 Ü berschriften/ 1.1 Überschrift en/1.1 Übersc hriften BDA/11 S tarten, Unterbr echen, Stoppen @ 0\mod_122 9417133049_ 9.doc @ 5070 @ 2 @ 1
5.10 Starting, Interrupting, Stopping
Pos: 7.22 /00010 Bedienungsa nleitungen Kapitels ammlungen/AS 450_control/ 0007 Bedien ung/AS450 Mo dul Starten Unter brechen Stopp en @ 0\mod_1 22941719678 3_9.doc @ 5076 @ @ 1
5.10.1 Starting
Press the (B11) start button.
- The LED green over the (B11) button lights up.
- The (Aa) display shows that the machine is running up to the preset value.
- During the sieving time the amplitude and/or sieve base acceleration are kept
at a constant level within the set tolerance.
5.10.2 Interrupting / Pause Function
Press the STOP/key (B12) once.
- The red LED over the (B12) button lights up.
- The set levels remain visible.
- Press the start button (B11) to continue the sieving operation.
5.10.3 Stopping / Stand-by Function
Press the (B12) stop button twice.
- The red LED over the (B12) button lights up.
- The entire display turns off.
Press the (B11) start button again to activate the LED displays.
You can now enter new settings.
Press the (B11) start button a second time.
The function runs as during start-up.
Pos: 7.23 /00005 Ü berschriften/ 1.1 Überschrifte n/1.1 Überschrift en BDA/11 Ei nstellen der Si ebzeit @ 0\m od_1229417790 014_9.doc @ 5 082 @ @ 1
5.11 Setting the sieving time
Pos: 7.24 /00010 Bedienungsa nleitungen Kapitels ammlungen/AS 450_control/00 07 Bedienung/ AS450 Modul Si ebzeit einstelle n @ 0\ mod_122941782260 8_9.doc @ 50 88 @ @ 1
Fig. 12: Setting undefined sieving time/sieving time
When the AS450 is put into operation for the first time, the sieving time is not yet
defined.
-- appears in the display (At).
The sieving timecan be set from 1 to 99minutes.
Use the - key (B5) to reduce the time down to 1 minute.
Use the + key (B6) to increase the time up to 99 minutes.
B5
B6
At
B5
B6
At