Operating the machine
20
Fig. 8: Graphic Representation of the Control Panel Connection
Pos: 7.9 /00005 Üb erschriften/1.1 Ü berschriften/ 1.1 Überschrifte n BDA/11 Übersic htstabelle der Bedienel emente und der A nzeige @ 0\ mod_1228990697 273_9.doc @ 4978 @ @ 1
5.5 Overview Table of the Operating Elements and the Display
Pos: 7.10 /00010 Bedienungsa nleitungen Kapitels ammlunge n/AS450_control/ 0007 Bedien ung/AS450 Mo dul Übersichtstabelle der Bedienf elder und der A nzeigeelemente @ 0\mod_ 12290088414 57_9.doc @ 5006 @ @ 1
B1
PROG - Key for calling up the preset sieve parameters (P1-P9 or on) and for ending
programming without saving the parameters.
Am
MEMORY display indicates the selected program P1-P9 or on. When the AS450 is
controlled by the EasySieve® software program, ES appears in the display.
B2
SET - key for activating the adjusting mode for the preselected program places P1-P9
and storing the parameters after programming.
B3
key reduces the vibration amplitude (0.2 - 2.2mm), accuracy ±0.1 mm and/or
sieve base acceleration in “g”
Aa
Amplitude display indicates the vibration amplitude and/or sieve bottom acceleration
in “g”.
B4
+ key increases the vibration amplitude, 0.2 - 2.2mm, accuracy ±0.1 mm and/or
sieve bottom acceleration in “g”
B5
key reduces the sieving time, 1 - 99min.
At
Time display shows the preselected sieving time 1 - 99min.
B6
+ key increases the sieving time, 1 - 99min.
B7
Key switches the interval enterprise ON, left LED lights up.
B8
Key switches the interval operation OFF, right LED lights up
B9
key reduces the interval time, 10 - 99sec.
Ai
Interval display shows the preselected interval time 10 - 99sec.
B10
+ key increases the interval time, 10 - 99sec.
B11
START key starts the sieving operation and the green LED lights up.
B12
STOP key stops and ends the sieving operation and the red LED lights up.
B13
B13
B14
B14